← Back to Search

1992 Ford F-150 5.0L V8 4x2 4AT

The 1992 Ford F-150 5.0L V8 4x2 4AT is a 5.0-liter V8 pickup truck with a 4-speed automatic and rear-wheel drive. It is rated at 14 mpg combined.

EPA fuel-economy estimates are 13 mpg city and 17 mpg highway (14 mpg combined).

Spec Value
Vehicle
Body TypePickup
PowertrainGas
Engine
Engine Type5.0L V8
Displacement5 L
Drivetrain
Drive TypeRear-wheel drive (4x2)
Transmission
Transmission4-speed automatic
Fuel Economy
City13 MPG
Highway17 MPG
Combined14 MPG
Recommended FuelRegular unleaded

Safety & Recalls

NCAP safety ratings

Overall Not rated
Frontal crash Not rated
Frontal – driver ★★★★★
Frontal – passenger ★★★★★
Side crash Not rated
Rollover Not rated
Tested variant: 1992 Ford F-150 2-DR.

Recalls

9 recalls on file with NHTSA for the 1992 Ford F-150. Not every recall applies to every trim or VIN — check yours at nhtsa.gov/recalls.

May 11, 2009 · EXTERIOR LIGHTING:HEADLIGHTS

DOPE, INC. IS RECALLING 42,540 COMBINATION CORNER AND BUMPER LAMP ASSEMBLIES OF VARIOUS PART NUMBERS SOLD FOR USE AS AFTERMARKET EQUIPMENT FOR VARIOUS PASSENGER VEHICLES. THESE HEADLAMPS FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, "LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT." THESE LAMPS DO NOT CONTAIN THE REQUIRED AMBER SIDE REFLECTORS.

Consequence: DECREASED LIGHTING VISIBILITY MAY RESULT IN A VEHICLE CRASH.

Remedy: DOPE, INC. WILL NOTIFY OWNERS AND OFFER A FULL REFUND FOR THE NONCOMPLIANT COMBINATION LAMPS. THE SAFETY RECALL BEGAN ON JULY 28, 2009. OWNERS MAY CONTACT DOPE, INC. AT 1-626-272-1798.

NHTSA campaign 09E025000

Apr 7, 2009 · EXTERIOR LIGHTING

SABERSPORT IS RECALLING 16,270 COMBINATION CORNER AND BUMPER LAMP ASSEMBLIES OF VARIOUS PART NUMBERS SOLD FOR USE AS AFTERMARKET EQUIPMENT FOR VARIOUS PASSENGER VEHICLES. THESE HEADLAMPS FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, "LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT." THESE LAMPS DO NOT CONTAIN THE REQUIRED AMBER SIDE REFLECTORS.

Consequence: DECREASED LIGHTING VISIBILITY MAY RESULT IN A VEHICLE CRASH.

Remedy: SABERSPORT WILL NOTIFY OWNERS AND OFFER A FULL REFUND FOR THE NONCOMPLIANT COMBINATION LAMPS. THE SAFETY RECALL BEGAN ON MAY 11, 2009. OWNERS MAY CONTACT SABERSPORT AT 1-909-598-7589.

NHTSA campaign 09E012000

May 24, 2006 · EXTERIOR LIGHTING

CERTAIN CK MOTORSPORTS COMBINATION HEADLIGHTS, CLEAR CORNER, BUMPER, AND SIDE MARKER LIGHTS SOLD AS REPLACEMENT LAMPS FOR USE ON THE PASSENGER VEHICLES LISTED ABOVE. SOME COMBINATION LAMPS THAT ARE NOT EQUIPPED WITH AMBER SIDE REFLECTORS FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT.

Consequence: WITHOUT THE AMBER REFLECTORS, THE VEHICLE WILL BE POORLY ILLUMINATED, POSSIBLY RESULTING IN A VEHICLE CRASH WITHOUT WARNING.

Remedy: CK MOTORSPORT WILL NOTIFY OWNERS AND REPLACE THE NONCOMPLIANT LAMPS FREE OF CHARGE. THE RECALL BEGAN ON JULY 1, 2006. OWNERS MAY CONTACT CK MOTORSPORT AT 1-909-610-7211.

NHTSA campaign 06E049000

Jul 19, 2001 · FUEL SYSTEM, GASOLINE

THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.

Consequence: SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.

Remedy: FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE ALREADY HAS MORE THAN 150,000 MILES, THIS OVERAGE WILL LAST UNTIL DECEMBER 31, 2001. IF THE VEHICLE IS EXPERIENCING A FUEL CROSS-FLOW CONDITION, DEALERS WILL REPAIR THE CONDITION FREE OF CHARGE.

NHTSA campaign 01I008000

May 22, 2001 · TIRES:TREAD/BELT

THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. EQUIPMENT DESCRIPTION: FORD IS REPLACING ALL FIRESTONE WILDERNESS AT 15, 16, AND 17 INCH TIRES MOUNTED ON FORD TRUCKS AND SUVS. FORD REPORTS TREAD SEPARATION CAN OCCUR DUE TO A COMBINATION OF THE SENSITIVITY OF THE TIRE DESIGN TO STRESS, AGING, AND MANUFACTURING DIFFERENCES BETWEEN PLANTS. FORD IS REPLACING THESE TIRES TO PREVENT POSSIBLE PREMATURE TIRE FAILURE. VEHICLE DESCRIPTION: THE VEHICLES LISTED BELOW MAY HAVE BEEN ORIGINALLY EQUIPPED WITH FIRESTONE WILDERNESS AT TIRES OR MAY HAVE HAD WILDERNESS AT TIRES INSTALLED DURING THE FIRESTONE RECALL LAUNCHED IN AUGUST 2000. CERTAIN 1991 THROUGHT 2002 FORD EXPLORER CERTAIN 2001 THROUGHT 2002 EXPLORER SPORT, AND SPORT TRAC CERTAIN 1997 THROUGH 2002 MERCURY MOUNTAINEER CERTAIN 1991 THROUGH 2001 RANGER CERTAIN 1999 THROUGH 2001 EXPEDITION CERTAIN 1991 THROUGH 1994, AND 1997 MODEL YEAR F-SERIES CERTAIN 1991 THROUGH 1994 BRONCO NOTE: BOTH ORIGINAL EQUIPMENT AND REPLACEMENT TIRES ARE AFFECTED.

Consequence: SHOULD THE TREAD SEPARATE AT HIGHWAY SPEEDS, A VEHICLE CRASH COULD OCCUR, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.

Remedy: THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON MARCH 31, 2002. HOWEVER, CUSTOMERS CAN CONTACT FORD AT 1-877-917-3673 OR GO ON-LINE TO WWW.FORD.COM FOR POSSIBLE ASSISTANCE.

NHTSA campaign 01X001000

Aug 21, 2000 · TIRES:TREAD/BELT

TIRE DESCRIPTION: FIRESTONE WILDERNESS AT, SIZE P235/75R15, PRODUCED AT THE DECATUR, ILLINOIS TIRE PLANT AND ALL FIRESTONE RADIAL ATX AND RADIAL ATX II TIRES, SIZE P235/75R15. OPERATION OF THESE TIRES AT LOW INFLATION PRESSURES, HIGH SPEED, AND IN HOT WEATHER, CAN CONTRIBUTE TO SEPARATION OF THE TIRE TREAD.

Consequence: IF THE TREAD SEPARATES FROM THE TIRE, THE DRIVER CAN LOSE CONTROL OF THE VEHICLE, POSSIBLY RESULTING IN A CRASH CAUSING INJURY OR DEATH.

Remedy: THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON AUGUST 29, 2001. HOWEVER, CUSTOMERS SHOULD CONTACT FIRESTONE CUSTOMER SERVICE AT 1-800-465-1904 FOR POSSIBLE ASSISTANCE.

NHTSA campaign 00T005000

Sep 7, 1994 · PARKING BRAKE:CONVENTIONAL

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

NHTSA campaign 94V169001

Aug 2, 1993 · FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

NHTSA campaign 93V125000

Jan 14, 1992 · STRUCTURE:BODY:DOOR

WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.

Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.

Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.

NHTSA campaign 92V006000

493 owner complaints to NHTSA for the 1992 Ford F-150

Owner Complaints

493 owner complaints filed with NHTSA for the 1992 Ford F-150 (22 mention a crash, 40 a fire, 12 an injury). See all on nhtsa.gov

Most-cited areas
Fuel System234
Gasoline228
Electrical System49
Engine And Engine Cooling35
Hydraulic35
Service Brakes35
A complaint can cite more than one area.
Most recent complaints
Feb 13, 2019 · Engine And Engine Cooling
“TL* THE CONTACT OWNS A 1992 FORD F-150. THE CONTACT INSTALLED A NEW CONTINENTAL CONTITECH SERPENTINE BELT IN THE VEHICLE FROM AUTO ZONE. THE BELT FAILED AND TORE INTO PIECES AFTER 65 MILES OF DRIVING…”
Sep 5, 2017 · Fuel/Propulsion System
“1992 F150 XLT LARIAT 302. DUEL TANKS. I USE THE REAR TANK AND NOT THE FRONT ONE. THIS WEEKEND MY TRUCK IS RUNNING GAS WILL POUR OUT OF THE FRONT TANK AT THE GAS CAP. I TOOK BOTH CAPS OFF SO THERE WAS…”
Feb 22, 2017 · Fuel/Propulsion System
“I HAVE NOTICED A STRONG SMELL OF GAS WHEN EXITING VEHICLE AFTER USE. A FEW DAYS LATER SAW GAS COMING FROM FRONT TANK FILLER. CHECKED CAP WAS ON PROPERLY. THEN I NOTICED THAN FUEL CONTINUED TO SPILL…”
Sep 8, 2016 · Fuel/Propulsion System
“FUEL FROM REAR TANK PUMPS TO FRONT TANK AND OVER FILLS FRONT TANK SPILLING ON GROUND”
Mar 31, 2016 · Fuel/Propulsion System
“REAR FUEL TANK DUMPING GAS INTO FRONT TANK CAUSING THE FRONT TANK TO OVER FLOW”

Complaints are unverified reports submitted to NHTSA by owners. They cover the whole model year, not a specific trim, and a count alone doesn't show how common a problem is.

Source: US National Highway Traffic Safety Administration (nhtsa.gov), matched as 1992 FORD F-150. US-market vehicles only; data cached for up to 7 days.

← Back to Search